Arc Ratings


Arc Thermal Performance Value (ATPV) Explained: What It Means and How to Use It for FR Garment Selection

Arc ratings, expressed as either arc thermal performance value (ATPV) or Energy to Breakopen Threshold (EBT), are among the most important values on an arc-rated and flame resistant (AR/FR) garment label because they help employers match the garment’s protection to the identified arc-flash hazard. ATPV tells you how much arc flash energy a garment can withstand before enough heat transfers through the fabric to cause the onset of a second-degree burn. Selecting garments with insufficient arc ratings leaves workers inadequately protected and creates a compliance gap that an arc flash event will expose.
This guide explains what ATPV means, how it differs from EBT, how to read it on a label, and how to use it to drive garment specification decisions across a managed FR clothing program.

ATPV & EBT: Two Types of Arc Ratings, One Level of Protection

Arc ratings are expressed as either ATPV or EBT. Both indicate the level of protection a fabric or fabric system provides against arc flash. The difference is the failure mode reached first during the testing – not the level of protection provided at the reported arc rating.

ATPV: Heat Transfer Through Intact Fabric

ATPV measures the incident energy at which there is a 50% probability of allowing sufficient heat transfer to cause the onset of a second-degree burn. When an arc rating is reported as ATPV, the burn threshold is reached before the fabric breaks open.. The relevant failure mode is heat transfer through the material to the skin beneath, not a hole or tear.

EBT: Fabric Breakopen

EBT, or Energy Breakopen Threshold, measures the incident energy at which there is a 50% probability that the fabric will break open. An arc rating is reported as EBT when the garment fabric develops a hold before enough heat transfers through to reach the ATPV threshold. ATPV and EBT indicate equivalent protection at or below the reported arc rating. The difference is the failure mode the fabric reaches first during testing.

The arc rating printed on the garment label is whichever threshold is reached first during testing: ATPV burn threshold or EBT breakopen threshold. The reported value is the arc-rating used to guide garment selection.

Metric What Is Measured Probability at Threshold Typical Label Use How to Interpret
ATPV Sufficient heat transfer through fabric to cause the onset of a second-degree burn 50% probability of 2nd-degree burn onset Reported arc rating when burn threshold is reached before breakopen Indicates the level of arc-flash protection provided by the fabric; the garment’s arc rating should meet or exceed the incident energy
EBT Fabric breakopen, generally defined as a hole meeting the applicable test criteria 50% probability of breakopen Reported arc rating when fabric breakopen occurs before burn threshold Provides equivalent protection as an ATPV rating of the same value; the garment’s arc rating should meet or exceed the identified incident energy
Arc Rating The protective value determined through arc testing and reported as either ATPV or EBT Based on the threshold reached first during testing The value printed on the garment label in cal/cm² and identified as ATPV or EBT Use the reported arc rating to select clothing that meets or exceeds the applicable PPE Category minimum or calculated incident energy

What Is Arc Thermal Performance Value?

ATPV is the arc flash incident energy level, measured in cal/cm2, at which a fabric or fabric system has a 50% probability of allowing sufficient heat transfer to cause the onset of a second-degree burn. It is determined through standardized arc flash testing under ASTM F1959/F1959M and is one of the two ways an arc rating may be reported.

The 50% probability framing matters. Arc-rated clothing is selected so its arc rating meets or exceeds the potential incident energy exposure. ATPV is a statistical test result, not an indication that the garment’s protection abruptly ends at a precise energy level.

The unit of measurement is cal/cm2 (calories per square centimeter). A calorie is a unit of energy. Arc flash produces intense radiant and convective heat, and cal/cm2 expresses the energy deposited per square centimeter of a surface during the event. A higher ATPV indicates that the material provides protection against higher levels of incident energy before reaching that 50% burn-onset probability.

One clarification that prevents a common specification error: ATPV is a type of arc rating, not a separate category. Every arc-rated garment must display its arc rating on its label, expressed as either ATPV or EBT. Both indicate the material’s level of arc-flash protection but are determined based on different failure modes.

How Arc Ratings Connect to NFPA 70E PPE Categories

NFPA 70E provides two methods for selecting arc-flash PPE: the Incident Energy Analysis and the PPE Category Method. When the PPE Category Method is used, arc-rated clothing and equipment are grouped into four categories, each with a minimum required arc rating.CAT 2 garments are commonly used for industrial daily wear when they align with the employer’s arc-flash risk assessment.

PPE Category Minimum Arc Rating Example Garment Ensemble
CAT 1 4 cal/cm² Arc-rated shirt and pants or arc-rated coverall
CAT 2 8 cal/cm² Arc-rated shirt and pants or arc-rated coverall
CAT 3 25 cal/cm² Arc-rated clothing system or arc flash suit with a minimum 25 cal/cm² system arc rating
CAT 4 40 cal/cm² Arc-rated clothing system or arc flash suit with a minimum 40 cal/cm² system arc rating

Note: This table is simplified and reflects typical garment applications. It does not list all required PPE.

IMPORTANT: The required protection applies to the full PPE ensemble

The selected clothing and other PPE must satisfy the requirements for the applicable category. When garments are layered to achieve a higher system arc rating, their individual ratings cannot simply be added together. The combined protection must be established through testing of the specific layered system.

Incident Energy Analysis Method

Under the Incident Energy Analysis Method, a qualified professional calculates the incident energy associated with the equipment and task, and the selected arc-rated clothing and PPE must have an arc rating that meets or exceeds that calculated value. The PPE Category Method and Incident Energy Analysis Method are both recognized under NFPA 70E, but they are alternative methods and should not be combined for the same piece of equipment.

ASTM F1506 governs the performance and labeling specification for arc-rated protective garments referenced under NFPA 70E. Compliant garments carry the arc rating, fiber content, care instructions, and ASTM F1506 standard designation on the label. For clothing within the scope of ASTM F1506, the absence of that compliance statement should be flagged and verified with the manufacturer or supplier.

How to Read an Arc Rating on a Garment Label

What a Compliant Arc-Rated Garment Label Must Display (ASTM F1506)

  • Arc rating value in cal/cm2, identified as ATPV or EBT
  • Fiber content
  • Manufacturer identification and garment tracking code
  • Country of origin
  • Care instructions including prohibited treatments
  • Statement of compliance with ASTM F1506

Some garments may also display additional information, such as the corresponding PPE Category, to make the protective rating easier for wearers to identify.

What NFPA 70E Compliance Looks Like on a Label

A properly labeled arc-rated garment provides the information needed to identify the garment, understand its protective rating, verify appliable standard compliance, and care for it properly.

For example, a garment may display an arc rating as 8.9 cal/cm2 (ATPV) along withASTM F1506 compliance, fiber content, manufacturer information, garment identification, and care instructions.

This specific format can vary by manufacturer, so employers should focus on whether the required information is present rather than expecting every label to look the same.

Red Flags on Arc-Rated Garment Labels

LABEL RED FLAGS: A garment described as ‘flame resistant’ without an arc rating in cal/cm2 should not be assumed to provide arc-flash protection. For dailywear arc-rated clothing within the scope of ASTM F1506, look for both the garment’s arc rating and a statement of ASTM F1506 compliance. If required information is missing or unclear, verify the garment’s compliance with the manufacturer or AR/FR clothing provider before approving it for use.

Practical Tip for Safety Managers

Applying ATPV to a Managed FR Clothing Program

Understanding ATPV at the individual garment level is the starting point. Applying arc-rating requirements consistently across a managed AR/FR clothing program depending on the job and hazards present helps employers maintain the appropriate level of protection across the workforce.

Define Arc Rating at the Program Level

Arc rating requirements should be established based on the employer’s hazard assessment and reflected in the approved garment assortment for the program. Rather than leaving workers to determine which protective rating is appropriate, employers can used managed AR/FR clothing programs, like Tyndale Enterprise and Business solutions to limit garment selection to options that meet the established requirements. This helps maintain consistency and ensure strict budgetary control when employees order replacement garments, select different styles, or move between approved product options based on personal preference or comfort.

Dual-Hazard Programs Require Protection for Both Hazards

Some workers may be exposed to both arc flash and flash fire hazards. In these environments, employers should select clothing that meets the applicable requirements for each identified hazard.

ASTM F1506 establishes performance requirements for clothing used for protection against electrical arc hazards, while NFPA 2112 establishes requirements for garments designed to protect against short-duration thermal exposures from fire. A garment that meets ASTM F1506 is not automatically compliant with NFPA 2112 and vice versa. The garment label must explicitly state both certifications. Specifying a single-standard garment in a dual-hazard environment creates a compliance gap that will surface during an incident investigation or OSHA inspection.

Layering Systems and System Arc Ratings

When AR/FR garments are worn as a layered system, the combination may provide greater arc-flash protection than either garment alone. However, individual garment ratings cannot simply be added together to determine the system arc rating. The specific combination must be arc tested in the configuration in which it will be worn. Tyndale’s Arc Flash Layering Tool provides tested system arc ratings for qualifying garment combinations, helping workers identify approved layers that meet their required level of protection.

Maintaining Protection Throughout the Garment Lifecycle

Selecting the appropriate arc rating is only the starting point. AR/FR garments must also be properly worn, cared for, inspected, and replaced when they are no longer suitable for service. Damage, improper use, or failure to follow garment care instructions can affect whether a garment should remain in use.  A managed FR clothing program can help employers establish consistent garment requirements and keep replacement orders within the company’s approved product selection.

Maintain Visibility Into Approved Arc-Rating Clothing

Safety and procurement teams should be able to verify the protective requirements based on the hazard risk assessment. Managers should maintain arc rating documentation for every garment in circulation. That means garment spec sheets, certification records, and inspection logs available for OSHA review. Tyndale’s managed program provides this documentation as a built-in service. When an inspector asks to see compliance records for the FR garments worn by a 500-person field crew, the answer should not require a manual search through purchase orders.

Managed AR/FR Clothing Programs

Your Arc-Rating Requirements.
A Program That Fits.

Work with a Tyndale Program Specialist to incorporate your established arc-rating requirements into a managed AR/FR clothing program that supports your workforce.



Talk to a Program Specialist 

Quick Reference: Arc Rating and PPE Category Cheat Sheet

Use this quick reference guide to review minimum PPE Category arc ratings and the key differences between ATPV and EBT. Garment selection should always be based on the employer’s hazard risk assessment and established arc-flash protection requirements.

PPE Category Minimum Arc Ratings

PPE Category Minimum Arc Rating Typical Garment Ensemble
CAT 1 4 cal/cm² Arc-rated long-sleeve shirt and pants or arc-rated coverall
CAT 2 8 cal/cm² Arc-rated long-sleeve shirt and pants or arc-rated coverall
CAT 3 25 cal/cm² Arc-rated clothing system or arc-flash suit with a minimum 25 cal/cm² system arc rating
CAT 4 40 cal/cm² Arc-rated clothing system or arc-flash suit with a minimum 40 cal/cm² system arc rating

ATPV vs. EBT at a Glance

Metric What It Measures Probability at Threshold Label Use Selection Guidance
ATPV Sufficient heat transfer through the fabric to cause the onset of a second-degree burn 50% probability of the onset of a second-degree burn Reported arc rating when the burn threshold is reached before fabric breakopen Select garments with arc rating that meets or exceeds the established requirements
EBT Fabric breakopen 50% probability of breakopen (hole or tear) Reported arc rating when breakopen occurs before the ATPV burn threshold Provides equivalent protection to an ATPV rating of the same value
Arc Rating Protective value determined through arc testing and reported as either ATPV or EBT Based on the threshold reached first during testing Value displayed on the garment label in cal/cm² Use the reported arc rating to select clothing that meets or exceeds the applicable PPE Category or calculated incident energy
  • Select garments with an arc rating that meets or exceeds the applicable PPE Category minimum or calculated incident energy When layered garments are used to achieve the required protection, rely on the tested system arc rating rather than adding individual garment ratings together.
  • When requirements or garment ratings are unclear, consult your safety professional or AR/FR clothing provider before selecting protective clothing

EXPLORE ARC-RATED FR CLOTHING

Browse Tyndale’s selection of AR/FR clothing, designed to meet a range of protection requirements and filterable by arc rating, PPE category, and fabric type.



Browse Arc-Rated FR Clothing 

Frequently Asked Questions

What is arc thermal performance value (ATPV)?

Arc thermal performance value (ATPV) is the arc-flash incident energy level, measured in cal/cm², at which a fabric or fabric system has a 50% probability of allowing sufficient heat transfer to cause the onset of a second-degree burn. ATPV is determined through standardized arc-flash testing under ASTM F1959/F1959M and is one of the two ways an arc rating may be reported.

What is the difference between ATPV and EBT?

ATPV and EBT are both ways an arc rating may be reported, but they reflect different failure modes during testing. ATPV is reported when the burn threshold is reached before the fabric breaks open. EBT is reported when fabric breakopen occurs before the ATPV burn threshold is reached. Neither is inherently more protective than the other; the important factor is the reported arc rating in cal/cm².

What does arc rating mean on an AR/FR garment?

The arc rating on an AR/FR garment indicates the level of protection the garment provides against arc flash, expressed in cal/cm² and identified as either ATPV or EBT. Arc ratings are determined through ASTM F1959/F1959M testing. The selected clothing must have an arc rating that meets or exceeds the applicable PPE Category minimum or calculated incident energy.

What arc rating do I need for NFPA 70E compliance?

The required arc rating depends on the employer’s arc-flash risk assessment and the PPE-selection method being used. Under the NFPA 70E PPE Category Method, CAT 1 requires a minimum arc rating of 4 cal/cm², CAT 2 requires 8 cal/cm², CAT 3 requires 25 cal/cm², and CAT 4 requires 40 cal/cm². Under the Incident Energy Analysis Method, the selected clothing must have an arc rating that meets or exceeds the calculated incident energy.

How do I read an arc rating on an AR/FR clothing label?

For daily-wear arc-rated clothing covered by ASTM F1506, look for the garment’s arc rating in cal/cm², identified as ATPV or EBT, along with manufacturer identification, garment identification or tracking information, fiber content, care instructions, and a statement of ASTM F1506 compliance. Some garments may also display the corresponding PPE Category. A garment described only as “flame resistant” should not be assumed to provide arc-flash protection; verify that an applicable arc rating and standard are identified.

""
✕

Calculate how much you can save with Tyndale’s AR/FR managed program solution.

 

✕