Support 24/7
Text 215-766-5665

✕

Support 24/7
Text 215-766-5665

Support 24/7
Text 215-766-5665

✕

Support 24/7
Text 215-766-5665

February 26, 2019

Do OSHA 1910.269 PPE Rules Impact Oil, Gas, and Other Industries?

OSHA’s 1910.269 ruling for the electric utility industry defines FR clothing as PPE–similar to 2010’s OSHA 1910.132 Enforcement Policy Memo regarding protection from flash fire in oil and gas well drilling, servicing, and production-related operations. In fact, the Preamble to the 1910.269 ruling introduces additional commentary from OSHA that paints […]
February 13, 2019

Tyndale’s Step by Step Guide to 1910.269 Compliance for Contractors

In April 2014, OSHA issued a ruling that clarified and expanded employers’ responsibility to protect employees from arc flash hazards.  This ruling – 29 CFR 1910.269 and 1926 subpart V, standards governing workplace safety in electric power generation, transmission and distribution work – has been enforced since August 31, 2015. […]
October 30, 2018

Top 10 Safety Violations Cited by OSHA for FY2018

The results are in – and it turns out that the most common workplace violations cited by OSHA in fiscal year 2018 are nearly identical to the 2017 list (and the 2016, list for that matter). The one difference:  “Eye and Face Protection” slips onto the list at number 10, […]
October 22, 2018

Do All FR Fabrics Offer Equal Protection?

In an earlier post, we showed you how a Westex DH shirt and pant stacked up against 100% cotton and a cotton/poly blend when it comes to protecting you against a flash fire hazard. The verdict was clear. Wearing non-FR clothing when a flash fire hazard exists could lead to […]
September 24, 2018

The Cost of Providing Arc Flash Protection

So far in this series, we have explored the many costs of an arc flash incident, the frequency of arc flash incidents, and the economic costs involved. Now we’d like to take a look at how you can mitigate the damage – both personal and economic – in the event […]
September 13, 2018

Not Wearing FR? See Why You Should.

If you’ve never witnessed a flash fire incident first-hand, it can be difficult to fully appreciate just how important it is to be fully protected by flame resistant clothing on the job. The direct injuries caused by the flames themselves can certainly be serious. But due to the relatively short […]
September 5, 2018

What Does an Arc Flash Injury Actually Cost Your Business?

So far we’ve looked at all the various costs an arc flash event can generate and just how often such events occur. Now we’d like to explore the economic impact an arc flash injury can have on your business. By far the greatest cost of any arc flash injury or […]
August 15, 2018

The Many Costs of an Arc Flash Incident

Being caught in an arc flash incident can result in devastating primary costs on an unprotected worker. At best, an employee’s life and that of their family is turned upside down as they undergo a long, painful recovery and rehab process. At worst, a family is left coping with the […]
March 1, 2018

Buyer Beware! Could Your FRC Be Counterfeit?

You wear FR clothing to stay safe on the job. But what if your FRC isn’t providing the protection you think it is? We’ve noted a growing and alarming online trend in recent months. Online companies – often based overseas – are selling what they claim to be flame resistant […]
December 27, 2017

What is Arc Flash Analysis?

If you wear arc-rated (AR) clothing and personal protective equipment (PPE) with a protective rating higher than a possible arc is likely to have, you can ensure you won’t be burned in the event of an arc flash. But how do you know what incident energy is possible, so you […]
August 4, 2015

Hugh Hoagland Addresses Comfort & Contamination in FRC

Although many utility employers began providing arc-rated clothing well before the new OSHA 1910.269, those who are now installing arc-rated clothing programs may face questions and sometimes friction from workers who are accustomed to wearing non-FR on the job.
March 31, 2015

What Does 1910.269 Say About Socks and Underwear?

OSHA’s 2014 1910.269 ruling marks a distinct departure from its predecessor. In fact, up until the new rule was promulgated, 1910.269 simply required that clothing “do no harm” in the event of an arc flash. In stark contrast, the 2014 ruling specifically requires employers to provide arc/flame resistant (FR) clothing […]
March 17, 2015

Tyndale’s Top Five OSHA 1910.269 Blog Posts

Since OSHA promulgated the new 1910.269 in April 2014, Tyndale has been hard at work partnering with employers to understand and gain compliance with the new provisions—helping workers return home to their families safely each night. Join thousands of readers in taking advantage of our top five OSHA 1910.269 blog […]
January 26, 2015

Training Video: FRC Care, Maintenance and Inspection

While many see OSHA’s update to standard 1910.269 as something that only affects the electric utility industry, OSHA’s changes are far greater reaching than many people may expect. In fact, the Preamble to OSHA’s recently updated standard 1910.269 ruling gives insight on the agency’s stance on proper care and maintenance […]
January 22, 2015

OSHA 1910.269 Resource Guide on Laundering FRC

OSHA’s update to standard 1910.269, which took effect in 2015,clarifies and expands the employer’s responsibility to provide and maintain appropriate arc-rated clothing to employees based on reliable estimates of workplace hazards. Tyndale can help employers understand key aspects of OSHA’s revised ruling to standard 1910.269 as it relates to FR […]
January 16, 2015

What is the Clo Value of FR Clothing?

One question many workers ask is how to stay warm in cold outdoor weather. Environmental conditions including outside temperature, wind speed and humidity level play a large part in how comfortable a worker will be. We’ve taken a look at heat stress, when heat needs to be released from the […]
January 5, 2015

Final Steps for OSHA 1910.269 Compliance

Important Note: As of February 2015, compliance dates have changed for enforcement of OSHA standard 1910.269. These changes impact dates listed in this post. Click here for complete details and updated deadlines. As part of OSHA’s 2014 final rule for 29 CFR 1910.269, OSHA mandated employers in electric power generation, transmission, […]
December 5, 2014

Tyndale’s 1-Page OSHA 1910.269 Resource Guide

Not sure if your employees are protected under final federal rule 1910.269? Tyndale can help! Tyndale is dedicated to protecting workers by partnering with employers to understand and gain compliance with the new requirements of the final rule. As a result, we’ve developed a fully-clickable digital one-page quick-reference guide to […]
November 7, 2014

Does Cost of 1910.269 Include FR Outerwear or Boots?

After OSHA’s update to standard 1910.269 was published, the meaning of flame resistant PPE, and specifically, how outerwear fits into this definition, has been open to interpretation – leaving many of us scratching our heads about safe and proper application. Additionally, many question whether or not OSHA 1910.269’s head-to-toe arc-rated […]
October 30, 2014

Tyndale PPE Guidance Featured in ISHN October 2014

Read Tyndale’s article, featured on page 44 of the October 2014 edition of Industrial Safety & Hygiene News (ISHN) Magazine, for guidance to employers looking to understand both OSHA’s 2014 update to 29 CFR 1910.269 and OSHA’s view of care and maintenance for PPE in a broader context—beyond the utility […]
October 29, 2014

4 Important Changes to NFPA 70E 2015 Edition for FRC

NFPA 70E has since been revised in 2018 and 2021. Please review our newer posts for the latest information. NFPA 70E is a voluntary standard advising on electrical safety in the workplace. This standard is geared toward workers and employers, and is designed to assist in the understanding and implementation […]
October 24, 2014

Tyndale in ISHN Magazine: Steps to Comply with 1910.269

OSHA’s 2014 updates to 29 CFR 1910.269 are generally embraced as much-needed measures to better protect the men and women who work on or near electric power lines. Read Tyndale’s article featured on page 44 of the July 2014 issue of Industrial Safety & Hygiene News Magazine (ISHN) for four […]
October 7, 2014

OSHA 1910.269: Why Industrial Laundry is Not the Answer

Under 1910.269 and 1926 subpart V ruling, OSHA clarified its stance that FR and arc-rated clothing should reasonably and appropriately be treated as Personal Protective Equipment (PPE). This designation reinforces the employer’s legal obligation to provide, pay for, and retain ultimate responsibility for care and maintenance of FR and arc-rated clothing. When […]
September 18, 2014

6 Critical Changes to OSHA 1910.269 Regarding FRC

On April 11, 2014, OSHA published to the Federal Register the final rule revising 29 CFR 1910.269 and 1926 Subpart V, related to the construction and repair of electric power generation, transmission and distribution in an effort to improve workplace safety. This recent change to OSHA 1910.269 updates the standard […]
July 31, 2014

1910.269 TRAINING VIDEO: FR Clothing Maintenance and Inspection

OSHA has published the final rule revising 29 CFR 1910.269 and 1926 Subpart V. This update is expected to save more than 20 lives and prevent 118 serious injuries each year by clarifying and expanding the employer’s responsibility to provide and maintain appropriate arc rated clothing for employees based on […]
July 28, 2014

3 Things to Look for When Signing a Contract with an AR / FR Clothing Supplier

Now that you’re on your way to selecting an arc-rated and flame resistant (AR / FR) clothing supplier, what should you know before signing the contract? This post outlines important aspects of the clothing purchasing process with regards to the terms and conditions you’re agreeing to, as well as the […]
July 21, 2014

What Is the Difference Between Arc-Rated Clothing and FR Clothing?

Understanding all of the acronyms for clothing and standards in the electric industry can make your head spin. One common question we get is: what is the difference between arc-rated and flame resistant clothing – if there is any difference at all? FR stands for “flame resistant clothing,” specifically. An […]
July 7, 2014

OSHA 1910.269 FR Clothing Update: 3 Reasons to Act Now

Important Note: As of February 2015, compliance dates have changed for enforcement of OSHA standard 1910.269. These changes impact dates listed in this post. Click here for complete details and updated deadlines. In April 2014, OSHA issued a ruling revising 29 CFR 1910.269 and 1926 subpart V, standards governing workplace […]
June 23, 2014

Access e-Hazard’s Side-By-Side Comparison of Changes to OSHA 1910.269 Standard

Important Note: As of February 2015, compliance dates have changed for enforcement of OSHA standard 1910.269. These changes impact dates listed in this post. Click here for complete details and updated deadlines. OSHA last issued rules for the construction of transmission and distribution installations in 1972. As you may now […]
June 13, 2014

Final OSHA 29 CFR 1910.269 Update: Care, Maintenance and Laundering of FR Clothing

During Electrical Safety Month in May, Tyndale began discussing key aspects of OSHA’s revised ruling of 1910.269 as it applies to FR clothing and has aimed to help employers understand its impact and how to properly protect employees. In this post, Tyndale identifies the last key component of OSHA’s final […]
June 6, 2014

Key OSHA 29 CFR 1910.269 Update: Employer Responsibility to Provide FR Clothing

During National Electrical Safety Month in May, Tyndale began discussing key aspects of OSHA’s revised ruling as it applies to FR clothing and during National Safety Month in June, Tyndale will continue to help employers understand how the new rule will impact their role, and the associated costs in properly […]
May 22, 2014

Key OSHA 29 CFR 1910.269 Update: Full Body Protection Against Arc Hazards

During National Electrical Safety Month, Tyndale has been discussing key aspects of OSHA’s revised ruling as it applies to FR clothing and seeks to help employers understand how the new rule will impact their role in properly protecting employees. The second key component of OSHA’s final ruling as it relates […]
May 20, 2014

Key OSHA 29 CFR 1910.269 Update: FR Clothing is Personal Protective Equipment

On April 11, 2014, OSHA published to the Federal Register the final rule revising 29 CFR 1910.269 and 1926 Subpart V, related to the construction and repair of electric power generation, transmission and distribution in an effort to improve workplace safety. In honor of National Electrical Safety Month, Tyndale will […]
May 15, 2014

Understanding Critical Changes to OSHA 1910.269 During Electrical Safety Month

May is National Electrical Safety Month, an important time to bring electrical safety awareness to our communities, to help educate the public and prevent injury. Coinciding with National Electrical Safety Month is the recent change to OSHA 1910.269 which updates the standard providing electrical safety guidance for those in the […]
✕