What is the Maximum Body Burn Percentage that Still Passes NFPA 2112?
September 19, 2024
For over 25 years, NFPA 2112—the “flash-fire standard”—has been essential in protecting workers from flash fire hazards by establishing minimum performance criteria for flame resistant (FR) garments.
NFPA 2112 sets clear guidelines for testing FR garments and the components that comprise the garments, including the fabric. In order to be NFPA 2112 certified, an entire garment and its components must undergo evaluation by a third-party organization, which verifies the garment has all of the required documentation to confirm correct and accurate test results that meet or exceed the NFPA 2112 standard.
NFPA 2112 outlines 17 test methods to ensure the protective qualities of flame resistant clothing. One of these is the pass/fail ASTM F1930 manikin test. This test method measures the average predicted body burn of a flame resistant fabric based on a laboratory flash fire simulation. But how does a garment get a passing grade for NFPA 2112’s allowable body burn percentage? Our Vice President of Technical, Scott Margolin, explains:
Understanding the maximum allowed body burn percentage
To pass NFPA 2112 requirements for predicted body burn, an entire protective garment must allow no more than a 50% body burn percentage when exposed to a three-second engulfment fire at 2 cal/cm2.
- The maximum allowable body burn percentage is 50% because survival rates plummet as total body surface area (TBSA) burns exceed this level.
- The test is three-seconds because, in theory, that is the upper limit of flash fire duration, and this duration affords the most accurate differentiation of fabric.
- 2 cal/cm2 is the level of heat energy required for this test. For reference, 1.2 calories per centimeter squared (1.2 cal/cm2) per second produces the onset of a second-degree burn.
When referring to “body burn percentage,” this means a burn injury expressed as a percentage of a manikin’s TBSA. It is important to note that only second- and third-degree burns are considered when measuring the body burn percentage; first-degree burns are not included in the assessment.
If the combination of second- and third-degree burns is at or below 50% of the TBSA, the garment passes this NFPA 2112 test. Therefore, it’s one step closer to compliance, and ultimately, certification.
Looking beyond NFPA 2112 compliance
A passing grade for NFPA 2112’s allowable body burn percentage doesn’t necessarily mean survival. 50% body burn – or even a percentage in the 40% range – is still catastrophic. While NFPA 2112 is a time-tested standard, it’s still a good idea to pay attention to the protective levels, as measured by body burn percentages, offered by individual garments.
Remember, merely complying with NFPA 2112 is only the first step on the way to remaining safe and protected on the job. Many NFPA 2112-certified garments on the market today can protect you with body-burn percentages well below the 50% maximum specified by NFPA 2112.
Tyndale provides an extensive selection of protective clothing, with most garments carrying NFPA 2112 certification. Maximizing protection is key to minimizing the risk of serious burn injuries due to flash fire hazards.