What is the flash fire manikin test?

Estimated reading: 1 minute

The manikin test, ASTM 1930, Test Method for Evaluation of Flame Resistant Clothing for Protection Against Flash Fire Simulations Using an Instrumented Manikin, is a commonly cited test method in NFPA 2112 (one of many). Fabrics are tested using the standard garment design a men’s coverall described in F1930. It uses an exposure heat flux of 84 kW/m2 (2.0 cal/cm2.sec) with an exposure time of three seconds. The average predicted body burn rating is calculated and reported in the fabric test results. If the tested garment delivers less than 50 percent total body burn rating, the fabric achieves a passing performance. For flash fire manikin test results of Tyndale’s M110T, click here.